(Summary description)For solar water heater, the reasons for water not hot are as follows: 1. There is a protective cover above the water heater or a large amount of local air smoke on the surface of the collector. 2. Step 2. The upper valve is damaged or not closed in place, so that the water tank is in a slowly upward or downward leakage state, and the hot water in the water tank overflows or leaks. 3. The water quality is not good. The existence of vacuum tube scaling reduces the heat collection efficiency. 4. The local air pollution is serious, and there is dust on the surface of vacuum pipe, which affects the heat collection. 5. All the hot water in the water tank is used up, that is, there is no basic water temperature, the water tank capacity is small and the water consumption is large. 6. Cloudy, rainy and foggy weather with low irradiance or short exposure time. 7. There is dust on the surface of gas collecting pipe. Remove and assemble the collection pipe and clean the surface with a small amount of water. 8. The vacuum degree of gas collecting pipe is reduced. The new vacuum tube needs to be replaced and cannot be used continuously. 9. There are few quality problems in the insulation layer, but they still exist, that is, there are large foaming holes in the insulation layer. The probability is generally less than one thousandth of a thousand. Consumers must choose brands or manufacturers with good quality to purchase. 10. The original solenoid valve of the water level controller can not be installed or programmed or controlled for water supply. The water supply is too large or mixed with the cooling water pipeline. In this case, professional personnel are needed for debugging and maintenance. Damaged parts shall be replaced in time to avoid affecting the use. 11. Leakage may also occur. If the water temperature and water level meter with automatic water supply function are installed, once the solar energy leaks, the solar energy is generally debugged during the installation process, mainly the water level meter debugging. As long as it is tested, the probability of water leakage is very small. The solution is as follows: 1. Shield removal or solar energy conversion; 2. Replace the water ball valve; 3. Clean the vacuum pipe; 4. Clean the surface of vacuum pipe and grid; 5. replace large capacity water heater or install electric heating system; 6. Analyze the weather and pay attention to the water volume on the water heater; 7. Start the auxiliary electric heating device in the solar water heater.

The reason and solution of water insulation of solar water heater

(Summary description)For solar water heater, the reasons for water not hot are as follows:
1. There is a protective cover above the water heater or a large amount of local air smoke on the surface of the collector.
2. Step 2. The upper valve is damaged or not closed in place, so that the water tank is in a slowly upward or downward leakage state, and the hot water in the water tank overflows or leaks.
3. The water quality is not good. The existence of vacuum tube scaling reduces the heat collection efficiency.
4. The local air pollution is serious, and there is dust on the surface of vacuum pipe, which affects the heat collection.
5. All the hot water in the water tank is used up, that is, there is no basic water temperature, the water tank capacity is small and the water consumption is large.
6. Cloudy, rainy and foggy weather with low irradiance or short exposure time.
7. There is dust on the surface of gas collecting pipe. Remove and assemble the collection pipe and clean the surface with a small amount of water.
8. The vacuum degree of gas collecting pipe is reduced. The new vacuum tube needs to be replaced and cannot be used continuously.
9. There are few quality problems in the insulation layer, but they still exist, that is, there are large foaming holes in the insulation layer. The probability is generally less than one thousandth of a thousand. Consumers must choose brands or manufacturers with good quality to purchase.
10. The original solenoid valve of the water level controller can not be installed or programmed or controlled for water supply. The water supply is too large or mixed with the cooling water pipeline. In this case, professional personnel are needed for debugging and maintenance. Damaged parts shall be replaced in time to avoid affecting the use.
11. Leakage may also occur.
If the water temperature and water level meter with automatic water supply function are installed, once the solar energy leaks, the solar energy is generally debugged during the installation process, mainly the water level meter debugging. As long as it is tested, the probability of water leakage is very small.
The solution is as follows:
1. Shield removal or solar energy conversion;
2. Replace the water ball valve;
3. Clean the vacuum pipe;
4. Clean the surface of vacuum pipe and grid;
5. replace large capacity water heater or install electric heating system;
6. Analyze the weather and pay attention to the water volume on the water heater; 7. Start the auxiliary electric heating device in the solar water heater.

  • Categories:Company news
  • Author:
  • Origin:
  • Time of issue:2019-05-13 19:54
  • Views:
Information
ensun
 
 
For solar water heater, the reasons for water not hot are as follows:
1. There is a protective cover above the water heater or a large amount of local air smoke on the surface of the collector.
2. Step 2. The upper valve is damaged or not closed in place, so that the water tank is in a slowly upward or downward leakage state, and the hot water in the water tank overflows or leaks.
3. The water quality is not good. The existence of vacuum tube scaling reduces the heat collection efficiency.
4. The local air pollution is serious, and there is dust on the surface of vacuum pipe, which affects the heat collection.
5. All the hot water in the water tank is used up, that is, there is no basic water temperature, the water tank capacity is small and the water consumption is large.
6. Cloudy, rainy and foggy weather with low irradiance or short exposure time.
7. There is dust on the surface of gas collecting pipe. Remove and assemble the collection pipe and clean the surface with a small amount of water.
8. The vacuum degree of gas collecting pipe is reduced. The new vacuum tube needs to be replaced and cannot be used continuously.
9. There are few quality problems in the insulation layer, but they still exist, that is, there are large foaming holes in the insulation layer. The probability is generally less than one thousandth of a thousand. Consumers must choose brands or manufacturers with good quality to purchase.
10. The original solenoid valve of the water level controller can not be installed or programmed or controlled for water supply. The water supply is too large or mixed with the cooling water pipeline. In this case, professional personnel are needed for debugging and maintenance. Damaged parts shall be replaced in time to avoid affecting the use.
11. Leakage may also occur.
If the water temperature and water level meter with automatic water supply function are installed, once the solar energy leaks, the solar energy is generally debugged during the installation process, mainly the water level meter debugging. As long as it is tested, the probability of water leakage is very small.
The solution is as follows:
1. Shield removal or solar energy conversion;
2. Replace the water ball valve;
3. Clean the vacuum pipe;
4. Clean the surface of vacuum pipe and grid;
5. replace large capacity water heater or install electric heating system;
6. Analyze the weather and pay attention to the water volume on the water heater; 7. Start the auxiliary electric heating device in the solar water heater.